Installation Guide
Tools Needed:
- Adjustable wrench
- Level
- Screwdrivers (flat and Phillips)
- Pliers
- Tape measure
- Drill with bits
Step-by-Step Installation
- Prepare Installation Area: Ensure cabinet opening meets specified dimensions and is level, clean, and dry.
- Remove Packaging: Remove all shipping materials, protective films, and transit bolts from the refrigerator.
- Water Line Connection: Connect to cold water supply using copper or plastic water line with proper shut-off valve.
- Electrical Connection: Connect to dedicated 115V, 60Hz, 15A grounded outlet. Do not use extension cord.
- Position Refrigerator: Carefully slide refrigerator into cabinet opening, ensuring proper clearance for door swing.
- Level and Secure: Adjust leveling legs to ensure refrigerator is perfectly level and secure in cabinet.
- Final Connections: Connect water line to ice maker, ensure all connections are tight and leak-free.
- Initial Setup: Allow refrigerator to stand upright for 4 hours before plugging in, then set temperature controls.
Specifications
Model Number | KDFE104DSS |
Type | Built-in Bottom Freezer Refrigerator |
Color/Finish | Stainless Steel |
Total Capacity | 24.8 cu. ft. |
Fresh Food Capacity | 17.5 cu. ft. |
Freezer Capacity | 7.3 cu. ft. |
Energy Rating | ENERGY STAR® Certified |
Annual Energy Use | 585 kWh |
Power Requirements | 115V, 60Hz, 15A |
Dimensions (HxWxD) | 84 x 48 x 24 inches |
Installation Depth | Counter Depth |
Water Filter | EveryDrop® Filter 4 |
Warranty Information
- Full Warranty: 1 year parts and labor
- Sealed System Warranty: 5 years on compressor and related parts
- Additional Coverage: Optional extended warranty available
For warranty service, contact KitchenAid Customer Service at 1-800-422-1230 or visit KitchenAid.com
Key Features
Preserva® Food Care System
Advanced temperature management system with multiple sensors and adaptive defrost to maintain optimal food preservation conditions.
ExtendFresh® Plus Temperature Management
Precise temperature control system with multiple cooling zones and adaptive technology to keep food fresher longer.
Factory Installed Ice Maker
High-capacity ice production system located in the freezer drawer for convenient access and maximum freezer space utilization.
LED Lighting
Energy-efficient LED lighting throughout refrigerator and freezer compartments for bright, cool illumination.
Adjustable Glass Shelves
Tempered glass shelves with spill protection that can be repositioned to accommodate items of various heights.
Humidity-Controlled Crispers
Independently controlled humidity drawers to maintain optimal moisture levels for fruits and vegetables.
Advanced Cooling Technology
Multi-Air Flow System
Evenly distributes cold air throughout all compartments for consistent temperature maintenance
Adaptive Defrost
Intelligent defrost system that operates only when needed, reducing energy consumption
Precise Temp Management
Digital temperature controls with 0.5°F increments for exact temperature settings
Door Alarm System
Audible alert if refrigerator or freezer door is left open for extended period
Energy Saving Mode
Optimized settings for reduced energy consumption during periods of low usage
Quick Cool Feature
Rapid cooling function to quickly chill newly added items without affecting other contents
Troubleshooting
Problem | Possible Cause | Solution |
---|---|---|
Refrigerator not cooling | Power issue, thermostat setting, dirty condenser coils | Check power supply, verify temperature settings, clean condenser coils |
Excessive frost in freezer | Door seal issue, frequent door openings, defrost system failure | Check door seals, reduce door openings, test defrost components |
Water dispenser not working | Water supply issue, clogged filter, frozen water line | Check water supply, replace filter, inspect for frozen lines |
Ice maker not producing ice | Water supply issue, clogged filter, mechanical obstruction | Verify water connection, replace filter, check for ice jams |
Unusual noises | Fan obstruction, compressor issues, loose components | Check evaporator and condenser fans, inspect compressor mounts |
Water leakage | Clogged drain line, damaged water connections, ice buildup | Clear drain line, check water connections, inspect defrost system |
Error Codes
- E0: Temperature sensor failure - Check sensor connections and operation
- E1: Evaporator sensor error - Inspect evaporator temperature sensor
- E2: Defrost sensor error - Check defrost termination sensor
- E3: Ambient sensor error - Verify ambient temperature sensor operation
- E4: Communication error - Check main control board connections
- F0: Fan motor error - Inspect evaporator fan motor and wiring
Manual Downloads
Current Model Manuals
KDFE104DSS
24.8 cu. ft. Built-in Refrigerator
KDFE204DSS
24.8 cu. ft. French Door
KDFE304DSS
27.8 cu. ft. Built-in
KDFE404DSS
30.1 cu. ft. Side-by-Side
Popular Previous Models
KDFE103DSS
24.5 cu. ft. Built-in
KDFE102DSS
24.2 cu. ft. Refrigerator
KDFE101DSS
23.8 cu. ft. Built-in
KDFE100DSS
23.5 cu. ft. Refrigerator